Expro Excellence
Fluids sampling and analysis
Non-reactive sampler enhanced mercury measurement
Customer challenges
  • Expro's client was appraising a new field in the North Sea for potential development
  • With a history of mercury in the region, concerns were raised about the potential impact on the process facility design and export route
  • Due to limitations on flaring, only a short Drill Stem Test (DST) was planned, which would limit the availability of representative samples at the surface
  • Representative mercury measurements were a priority objective for the test, but a full program of sampling and onsite analysis was also planned
Expro Excellence
  • Expro provided the Non-Reactive Sampler (NRS) to be integrated within the DST string using Expro's sampling carrier
  • Working with the client Expro's NRS was configured to ensure perfect integration with the 3rd party DST provider for triggering the samplers
  • Multiple NRS samples were taken for mercury and hydrogen sulfide measurements, with analysis conducted immeditately after tools were at the surface to minimize scavenging of reactive components
  • Expro's multi-skilled crew were able to deliver all bottomhole sampling and chemistry requirements, negating the need for separate NRS operators and reducing POB
Value to client
  • NRS measurements showed excellent agreement with each other
  • Mercury measurements conducted from the separator were confirmed to be lower than those obtained from the downhole NRS tools
  • The client had confidence in the concentrations reported from the NRS despite the short flow test
  • The client was able to proceed with their field development plans, factoring in the reservoir contaminant concentrations
  • NRS will now be included in all the client's future DSTs
Contact

Non-reactive sampler enhanced mercury measurement

In Brief
Development of downhole NRS in DST operation gives confidence in reservoir mercury concentrations during appraisal against measurements taken from separator lines
Product Line
  • Fluids sampling and analysis
Region
Europe and Sub Saharan Africa
Customer challenges
  • Expro's client was appraising a new field in the North Sea for potential development
  • With a history of mercury in the region, concerns were raised about the potential impact on the process facility design and export route
  • Due to limitations on flaring, only a short Drill Stem Test (DST) was planned, which would limit the availability of representative samples at the surface
  • Representative mercury measurements were a priority objective for the test, but a full program of sampling and onsite analysis was also planned
Expro Excellence
  • Expro provided the Non-Reactive Sampler (NRS) to be integrated within the DST string using Expro's sampling carrier
  • Working with the client Expro's NRS was configured to ensure perfect integration with the 3rd party DST provider for triggering the samplers
  • Multiple NRS samples were taken for mercury and hydrogen sulfide measurements, with analysis conducted immeditately after tools were at the surface to minimize scavenging of reactive components
  • Expro's multi-skilled crew were able to deliver all bottomhole sampling and chemistry requirements, negating the need for separate NRS operators and reducing POB
Value to client
  • NRS measurements showed excellent agreement with each other
  • Mercury measurements conducted from the separator were confirmed to be lower than those obtained from the downhole NRS tools
  • The client had confidence in the concentrations reported from the NRS despite the short flow test
  • The client was able to proceed with their field development plans, factoring in the reservoir contaminant concentrations
  • NRS will now be included in all the client's future DSTs
Contact

For further information, please contact:

[email protected]